Refrigeration Service and Repairs at Moldon

Project details

Category

Maintenance & Servicing

Date

October 2026

Location

Zimbabwe

Client

Moldon

Open multideck dairy chiller serviced by Isocool at Moldon

The Challenge

Moldon relies on a full line-up of display refrigeration to keep dairy, meat, vegetables, frozen goods and beverages at safe temperatures. Isocool was called in to service and repair eight display chillers and one coldroom on site.

On inspection, our technicians found that several units were overdue for maintenance. Condenser coils were heavily blocked with dust and lint, which restricts airflow, forces compressors to work harder and pushes up running costs. One chiller was also losing refrigerant through a leak at the filter drier flare connection.

The Solution

Our team checked system pressures on every unit and topped up R134a refrigerant where it was required. The leak on the filter drier flare connection was traced and repaired, restoring the chiller to a sealed, properly charged system.

The blocked condenser coils were thoroughly cleaned to restore airflow and heat rejection, and the coldroom was given a general inspection and service. One fridge was found to be draining into a makeshift container, so a made-to-measure drain pan (640 mm x 400 mm x 70 mm) was specified for fitting on a follow-up visit.

The Result

All eight display chillers and the coldroom were returned to service with correct pressures, clean condensers and no active leaks. Clean coils mean lower head pressures, less strain on compressors and lower electricity use.

Isocool also gave Moldon clear recommendations to protect the equipment going forward: a preventive maintenance programme with condenser cleaning at every visit, ongoing leak and refrigerant charge monitoring, and door seal checks on the display fridges.

Project Specs

Equipment: 8 display chillers and 1 coldroom | Refrigerant: R134a | Work: Pressure checks, refrigerant top up, leak repair, condenser coil cleaning, coldroom service | Fault found: Leak at filter drier flare connection | Client: Moldon